Simple, Rugged Quality

800-369-6233800-369-6233

Request for Quote

HV Series Blowdown Heat Recovery Systems (3,000 – 15,000 lbs/hr capacity)

  • HV type heat recovery system
    HV type heat recovery system
    6 models ranging from 3,000-15,000 lbs/hr capacity
     
  • Vertical type
     
  • ASME code welded combined flash tank and head exchanger vessel
     
  • 150 psi construction
     
  • 6”X8” hand hole for inspection
     
  • Temperature gauge panel continuously shows performance of unit and furnishes data to calculate savings
     
  • Customized inlet flow control manifold. Six boilers or more can easily be tied into one heat recovery system.

Madden Type HV Continuous Boiler Blowdown Heat Recovery Systems feature blowdown capacities up to 15,000 lbs. per hour. These HV series heat recovery systems work using the flash steam principle. When hot boiler blowdown enters the unit, it hits a baffle, this along with the pressure change causes some of the water to turn to flash steam. This flash steam is then sent off to the D/A tank to be reused. The remaining hot water is cooled with the U tube bundle in the bottom of the unit using cooling water. The cooled blowdown is then at statute limits for safe disposal and the resulting heated up cooling water is now boiler feed water supplied to the D/A tank.

Features

  • Recovers 90% of lost heat
     
  • Payback period of less than 12 months is common
     
  • No solids build up
     
  • ASME code welded flash tank and heat exchanger vessel, 150 psi construction Section VIII, Div. 1. With National Board Serial Number and “U” stamp
     
  • Safety pressure relief valve, normally set for 40 psi
     
  • Flash steam outlet flange
     
  • High water level alarm system (optional)
     
  • Pressure Gauge
     
  • Sight gauge for water level in flash tank
     
  • Baffle creates water turbulence
     
  • Manifold for mounting Orifice Meter or connecting other blowdown supply pipe, one or two manifolds can handle up to six boilers
     
  • Madden Orifice Meter continuous blowdown control (optional). One meter required for each boiler
     
  • 6” x 8” hand hole for float valve access and inspection
     
  • Continuous flow balanced pressure float valve with 316 stainless steel float and trim is specifically designed for blowdown service
     
  • Temperature gauge panel with three 3-1/2” gauges to monitor drain water, exchange water inlet and outlet temperatures, makes checking system efficiency easy
     
  • Heat exchanger coil, four 7/8” copper tubes with bronze headers at each end. Designed to provide even distribution of hot water to all four tubes to maximize thermal transfer.
  • (Optional 304 SS heat exchanger coil also available.)
     
  • Exchanger shell with flanged exchange water inlet and outlet provides swirling action in the water. The turbulence assures exchange water contact with the coil surfaces and improved efficiency.
     
  • Blowdown water discharge fitting and temperature bulb

HV Series

Model Number HV030 HV050 HV070 HV090 HV120 HV150
Blowdown Capacity lb/hr 3,000 5,000 7,000 9,000 12,000 15,000
A - (OAH) 77" 83" 89" 95" 104" 124"
B 49-5/8" 55-5/8" 61-5/8" 67-5/8" 76-5/8" 94-5/8"
C 15" 15" 15" 15" 15" 15"
D 16-1/2" 22-1/2" 28-1/2" 34-1/2" 43-1/2" 61-1/2"
E 17 21 25 29 35 46
F 13" 13" 13" 13" 13" 13"
G 3" FLG 1-1/2" 3" FLG 1-1/2" 4" FLG 1-1/2" 4" FLG 1-1/2" 4" FLG 1-1/2" 4" FLG 1-1/2"
H NPTF NPTF NPTF NPTF NPTF NPTF
I *1" *1" *1" *1" *1" *1"
J 3" FLG 3" FLG 4" FLG 4" FLG 4" FLG 4" FLG
K 1-1/2" 2" 2" 2" 2" 2"
Ship Weight in lbs. 1,200 1,300 1,400 1,500 1,700 1,900

* I Dimension 1-1/4" when Model 650 Orifice Meter is used
 
HV Series diagram
HV Series diagram

To learn more about our HV Series Blowdown Heat Recovery Systems, click here to contact us.

 
Back to Top

Need a Boiler Blowdown Separator in a rush?

Madden Manufacturing now holds some of our more popular designs in inventory. If you need an emergency replacement, or need a boiler blowdown separator in a rush for any reason, reach out to a sales rep or contact us directly to see what we can do. 

Contact Us

Recent Blog Posts

What are the advantages of using a vertical heat exchanger in a boiler blowdown heat recovery system

Solenoid driven diaphragm metering pumps vs. electric motor driven diaphragm metering pumps: Which is more cost effective for dosing chemicals?

What are B.T.U's and why are they important in boiler blowdown processes and cost savings?

View all Blog Posts