Three different styles and twenty standard models are available to match a Madden blowdown Heat Recovery System to your boiler system for the best performance and the most economical return on investment. Look at these Madden results:
Durable, time proven designs, built to take the punishment of continuous, 24 hour a day service for years.Hot, High pressure continuous blowdown water drained from the boiler, contains valuable heat energy. The continuous blowdown process helps control boiler water quality and operating efficiency by removing suspended and dissolved solids from the water in the boiler drum.
Recovery of up to 50% of the BTU's available may be accomplished by generating low pressure flash stream in a flash tank. This supply of stream can be used in boiler D/A tank or other low pressure steam applications. As the flash steam is generated, the blowdown condensate that remains is used to preheat the boiler feed water using a low pressure liquid heat exchanger. For smaller, lower pressure blowdown requirements, the HX Series heat recovery system utilize a higher pressure liquid to liquid heat exchanger without a flash tank to do the heat recovery job. The Madden sales representative will recommend the model you need to maximize your fuel savings potential.
Madden System Features
Type HX, HV and Type HC
The Type HX blowdown heat recovery systems are inexpensive, yet durable. The hot blowdown water passes through a self cleaning vertical heat exchanger coil. Fresh makeup water is the shell side counter flow cooling media. No flash steam is created in these simple heat exchangers. The Type HX are designed for blowdown flows up to 3,500 lbs. per hour from boilers up to 150 psi. ASME 150 psi shell construction. Copper or Stainless Steel coils available.Click to request a boiler blowdown heat recovery system proposal.
| Model Number | Capacity lbs/hour | Description |
| HC40-150 | 4,000 | Horizontal type, 304 SS U-tube type heat exchanger |
| HC80-150 | 8,000 | Horizontal type, 304 SS U-tube type heat exchanger |
| HC120-150 | 12,000 | Horizontal type, 304 SS U-tube type heat exchanger |
| HC160-150 | 16,000 | Horizontal type, 304 SS U-tube type heat exchanger |
| HC200-150 | 20,000 | Horizontal type, 304 SS U-tube type heat exchanger |
| HC240-150 | 24,000 | Horizontal type, 304 SS U-tube type heat exchanger |
| HC280-150 | 28,000 | Horizontal type, 304 SS U-tube type heat exchanger |
| HC320-150 | 32,000 | Horizontal type, 304 SS U-tube type heat exchanger |
| HC360-150 | 36,000 | Horizontal type, 304 SS U-tube type heat exchanger |
| HC500-150 | 50,000 | Horizontal type, 304 SS U-tube type heat exchanger |
| HV030A | 3,000 | Vertical type, copper coil heat exchanger |
| HV030B | 3,000 | Vertical type, 304 SS coil heat exchanger |
| HV050A | 5,000 | Vertical type, copper coil heat exchanger |
| HV050B | 5,000 | Vertical type, 304 SS coil heat exchanger |
| HV070A | 7,000 | Vertical type, copper coil heat exchanger |
| HV070B | 7,000 | Vertical type, 304 SS coil heat exchanger |
| HV090A | 9,000 | Vertical type, copper coil heat exchanger |
| HV090B | 9,000 | Vertical type, 304 SS coil heat exchanger |
| HV120A | 12,000 | Vertical type, copper coil heat exchanger |
| HV120B | 12,000 | Vertical type, 304 SS coil heat exchanger |
| HV150A | 15,000 | Vertical type, copper coil heat exchanger |
| HX400A | 2,500 | Vertical blowdown heat exchanger, copper coil |
| HX400B | 2,000 | Vertical blowdown heat exchanger, 304 SS coil |
| HX450A | 3,000 | Vertical blowdown heat exchanger, copper coil |
| HX450B | 2,500 | Vertical blowdown heat exchanger, 304 SS coil |
| HX470A | 3,500 | Vertical blowdown heat exchanger, copper coil |
| HX470B | 3,500 | Vertical blowdown heat exchanger, 304 SS coil |